Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment

  • 1
  • 2

Brand Name : YUYANG

Model Number : PMCC-B

Certification : ISO

Place of Origin : China

MOQ : 1 Set

Price : USD1500

Supply Ability : 100 Sets per month

Delivery Time : 15 days

Packaging Details : Plywood case

Product name : Pensky-Martens Closed-Cup Flash Point Apparatus

Test method : Pensky-Martens Closed-Cup

Test standard : ASTM D93

Operation : Manual

Condition : New

Warranty : 1 year

Maximum power consumption : 650W

Color : Grey

Contact Now

Manual Pensky-Martens Closed-Cup Flash Point Apparatus
Summary
Cheap Manual Pensky-Martens Closed-Cup Flash Point Apparatus is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
I. Main technical features
1. Manual Pensky-Martens Closed-Cup Flash Point Apparatus is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
II. Main technical specifications
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)℃/min;Controllable and adjustable.
4. Stirring rate: Procedure A: (90~120)RPM, Procedure B: (250±10)RPM
5. Oil cup:(1) Inner diameter: 50.7mm~50.8mm.
(2) Depth: 55.7mm~56.0mm
(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
(4) Capacity of testing oil:about 70ml
6. Igniting device:(1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer.Specifications are as below:
(1)Scale -5℃~110℃, division 0.5℃.
(2)Scale 20℃~150℃, division 1℃.
(3)Scale 90℃~370℃,division 2℃.
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10. Maximum power consumption:650W
III.Accessories
No. Item Unit Qty Remarks
1 Thermometer -5 ~ 110 ℃, each scale division is 0.5 ℃ Piece 1

GB / T261-2008

Standard requirement

2 Thermometer 20 ~ 150 ℃, each scale division is 1.0 ℃ Piece 1
3 Thermometer 90 ~ 370 ℃, each scale division is 2 ℃ Piece 1
4 Driving flexible shaft Piece 1
5 Latex tube Ф3 250mm Piece 3 One for alternate
6 5A fuse (Ф5 × 20) Piece 2
7 Thermometer adapter Set 1
8

Thermometer liner

(Cut suitable length of liner to wrap the lower end of the thermometer, so that the thermometer is just inserted into the thermometer adaptor)

Piece 5
Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment

Product Tags:

oil testing machine

      

oil analyzer equipment

      
Quality Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment for sale

Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN YUYANG INSTRUMENT CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)